Fiberglass and proprietary fiber fabric with a tacky natural rubber coating and 0.007" (0.18 mm) diameter brass wire insertion.
Applications
Recommended for use as hand hole, manhole, or tadpole gaskets, fire doors, access doors, and static boiler and door application, especially where steam is present. Suitable for low pressure steam, water, and other general services. Not suitable for ozone or UV light exposure.
| Performance Data | |
| TEMPERATURE, MAXIMUM | 400°F (204°C) |
| PRESSURE, MAXIMUM | 180 psi; (12.4 bar);(1.24 MPa);(12.7 kg/cm²) (In Steam Service) |
| MULLENS BURST STRENGTH D-751-89 | N/A |
| TENSILE STRENGTH N/A | N/A |
| DENSITY | 96 lbs/ft³ (1.54 g/cc) Typical |
| pH RANGE AT AMBIENT TEMPERATURE | 2 to 10 |
| DUROMETER, SHORE "A" ASTM D2240 | N/A |
| BOLT TORQUE | |
"M" Gasket Factor - 2.25 for all thicknesses |
|
"Y" Gasket Factor - 2200 psi (151.7 bar) for all thicknesses |
|
| Availability 40" (101.6 cm) wide continuous lengths (up to 50 yards)(45.7 m) with 1/16" (1.59 mm) thickness. Other thicknesses may be obtained by laminating one or more sheets. Approximate weight: 5 lbs/yd (2.5 kg/m) based on a 1/16" (1.59 mm) thickness. |
|